RETROFIT SURVEY FORMS AND PART NUMBERS

SURVEY FORMS

1 Door
Waste Oil
Survey Form

2 Door
Survey Form


E/Z Lift
2 Door
Survey Form

E/Z Lift
Survey Form


No opening, plain
Survey Form




Retrofits, for existing cast / ductile iron and rolled steel ring manholes
MODEL NUMBER
DESCRIPTION
NO OPENING
R36C
36"cover only, with handles (for cast iron ring)
R36S
36"cover only, with handles (for rolled steel ring)
1 DOOR
R361C
36" 1 door snap-tight cover, no containment (for cast iron ring)
R361S
36" 1 door snap-tight cover, no containment (for rolled steel ring)
R361C-GC
36" 1 door gravity cover, no containment (for cast iron ring)
R361S-GC
36" 1 door gravity cover, no containment (for rolled steel ring)
R36181C
36" 1 door snap-tight cover, 1-5 gallon containment (for cast iron ring)
R36181S
36" 1 door snap-tight cover, 1-5 gallon containment (for rolled steel ring)
1 DOOR WITH FUNNEL CONTAINMENT
R361C-WO
36" 1 door snap-tight cover with waste oil, funnel containment (for cast iron ring)
R361S-WO
36" 1 door snap-tight cover with waste oil, funnel containment (for rolled steel ring)
2 DOOR
R362C
36" 2 door snap-tight cover, no containment (for cast iron ring)
R362S
36" 2 door snap-tight cover, no containment (for rolled steel ring)
R36281C
36" 2 door snap-tight cover, 1-5 gallon containment (for cast iron ring)
R36281S
36" 2 door snap-tight cover, 1-5 gallon containment (for rolled steel ring)
R36271C
36" 2 door snap-tight cover, 2-5 gallon containment (for cast iron ring)
R36181S
36" 2 door snap-tight cover, 2-5 gallon containment (for rolled steel ring)
E/Z LIFT RETROFITS
R36C-HINGE
36" E/Z Lift cover only
R361C-HINGE
36" E/Z Lift cover, 1 door snap-tight cover, no containment
R362C-HINGE
36" E/Z Lift cover, 2 door snap-tight cover, no containment

Options:
ADD on OPTION
DESCRIPTION
GC
For Gravity access cover, example (R36271C-GC)
OH
For E/Z lift hinge cover
R362C
36" retrofit, 2 doors, no containments
R36181C
36" retrofit, 1 door, 1-5 gallon containment
R36281C
36" retrofit, 2 door, 1-5 gallon containment
R36271C
36" retrofit, 2 door, 2-5 gallon containments

Eliminate the cross threaded and broken off screw studs that exist with our Cam-loks to make the water tight seal again without breaking concrete.
When the 36", 39" or 42" retrofit is installed and the Cam-loks are tightened in a rotational alternating manner, the integrity of the seal will keep out the water and the cover should only have to be removed to replace the turbine motor.
Only the Snap-Tight cover needs to be removed to maintain the liquid probe or to visually inspect for any type of liquid or contamination. This eliminates the possibility of a person accidentally falling into the confined area and to have to lift the heavy cover.
The savings can be realized in low maintenance cost and no down time. Only one person needs to be there.
Leak detector can be removed - Line and Liquid probe testing can also be performed through the Snap-Tight opening.